{"id":976,"date":"2026-11-18T17:02:55","date_gmt":"2026-11-18T09:02:55","guid":{"rendered":"https:\/\/yaodamotor.com\/?p=976"},"modified":"2026-11-18T17:06:03","modified_gmt":"2026-11-18T09:06:03","slug":"three-phase-motor-storage-and-first-start","status":"publish","type":"post","link":"https:\/\/yaodamotor.com\/es\/three-phase-motor-storage-and-first-start\/","title":{"rendered":"Almacenamiento y primera puesta en marcha de motores trif\u00e1sicos: consejos de un fabricante de motores"},"content":{"rendered":"<style>\n.yaoda-article-toc{margin:26px 0 30px;padding:18px 22px;border:1px solid #dfe5ee;border-radius:8px;background:#f8fafc}\n.yaoda-article-toc summary{display:flex;align-items:center;justify-content:space-between;gap:16px;cursor:pointer;list-style:none;color:#133784;font-size:19px;font-weight:700;line-height:1.4}\n.yaoda-article-toc summary::-webkit-details-marker{display:none}\n.yaoda-article-toc summary:after{content:\"+\";font-size:22px;line-height:1}\n.yaoda-article-toc[open] summary:after{content:\"\u2212\"}\n.yaoda-article-toc ul{margin:14px 0 0 22px;padding:0}\n.yaoda-article-toc li{margin:7px 0;color:#4b5563}\n.yaoda-article-toc a{color:#064679;text-decoration:none}\n.yaoda-article-toc a:hover{text-decoration:underline;text-underline-offset:3px}\n<\/style>\n<details class=\"yaoda-article-toc\" open>\n<summary>Table of Contents<\/summary>\n<ul>\n<li><a href=\"#receiving-inspection\">At receiving, keep the evidence before anyone repairs the motor<\/a><\/li>\n<li><a href=\"#storage-moisture\">The warehouse does not have to be wet for the winding to absorb moisture<\/a><\/li>\n<li><a href=\"#bearing-storage\">A stationary bearing can deteriorate while the motor is idle<\/a><\/li>\n<li><a href=\"#insulation-resistance\">Use the insulation reading to make a decision<\/a><\/li>\n<li><a href=\"#first-start-checks\">Prove the installation before full load is applied<\/a><\/li>\n<li><a href=\"#warranty-evidence\">What Yaoda needs when the first start fails<\/a><\/li>\n<\/ul>\n<\/details>\n<p>A three-phase motor can leave our test bench with balanced current, acceptable no-load vibration and recorded insulation resistance, then fail during its first shift after six months in a warehouse. From a manufacturer's point of view, that failure is rarely a mystery. The motor has not changed since despatch. The conditions around the winding, bearings and installation have changed.<\/p>\n<p>Yaoda manufactures <a href=\"https:\/\/yaodamotor.com\/products\/three-phase-asynchronous-motor\/\">three-phase induction motors<\/a> for distributors and industrial end users. When a customer reports a first-start failure, our engineers need to separate a manufacturing defect from moisture absorption, bearing deterioration, transport damage and site wiring. This is the advice we give before the motor is put into storage or energised for the first time.<\/p>\n<figure class=\"wp-block-image aligncenter size-large is-resized\">\n  <img fetchpriority=\"high\" loading=\"eager\" decoding=\"async\" width=\"1600\" height=\"1066\" class=\"wp-image-426\" src=\"https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room.webp\" alt=\"Three-phase motors at the Yaoda Motor manufacturing facility\" style=\"width:600px;max-width:100%;height:auto\" srcset=\"https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room.webp 1600w, https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room-300x200.webp 300w, https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room-1024x683.webp 1024w, https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room-768x512.webp 768w, https:\/\/yaodamotor.com\/wp-content\/uploads\/2026\/05\/motor-electrical-control-testing-room-1536x1024.webp 1536w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><figcaption class=\"wp-element-caption\">Factory test records establish the motor's condition at despatch. The first-start check must establish what has changed since then.<\/figcaption><\/figure>\n<h2 id=\"receiving-inspection\">At receiving, keep the evidence before anyone repairs the motor<\/h2>\n<p>An end user or distributor should first photograph the outside of the package. Crushed corners, a broken pallet, torn moisture protection or strapping that has pressed against the shaft all help explain later damage. Once the packaging is opened, photograph the shaft extension, flange face, terminal box, fan cover and mounting feet before cleaning the machine.<\/p>\n<p>Compare the nameplate with the purchase order rather than with the model name on the packing list alone. Check power, voltage, frequency, poles, frame, mounting arrangement, protection class, cooling method and serial number. Two motors in the same frame can have different terminal-box positions, shaft extensions, encoders or winding arrangements. Installing the wrong unit may damage the driven machine even though the nameplate looks familiar.<\/p>\n<p>Write down the receiving date and the serial numbers that go into stock. That date should stay attached to the motor or its permanent warehouse record because grease shelf life, heater operation and warranty evidence all depend on how long the motor has been waiting for installation.<\/p>\n<h2 id=\"storage-moisture\">The warehouse does not have to be wet for the winding to absorb moisture<\/h2>\n<p>Motors \"breathe\" as the surrounding temperature changes. Warm, humid air can enter through seals and pressure-equalising paths; when the motor cools, condensation can form inside a winding that appears perfectly dry from the outside. This is common in coastal sites, unheated stores and buildings where doors are opened to humid outside air.<\/p>\n<p>Store the motor indoors, off the floor and away from roof leaks, drainage paths and washdown areas. Keep the shaft and terminal box covered, but do not seal every opening so tightly that trapped moisture cannot leave during a controlled drying procedure. Protect the machine from airborne dust, metal particles and vibration from nearby machinery.<\/p>\n<p>If anti-condensation heaters are fitted, energise them only according to the motor documentation. The objective is to keep the winding above the dew point, not to bake it continuously. Place a thermometer and humidity logger near the stored motor when the warehouse is not climate-controlled. A six-month old invoice is not evidence that the motor stayed dry; a temperature and humidity record is much more useful.<\/p>\n<h2 id=\"bearing-storage\">A stationary bearing can deteriorate while the motor is idle<\/h2>\n<p>Long storage keeps rolling elements pressed into a small part of the bearing race. Combined with vibration, temperature cycling or inadequate grease condition, this can leave false-brinelling marks that become noise and vibration after the motor starts. Grease also has a storage life, and a sealed bearing being unused does not mean it is unaffected by time and temperature.<\/p>\n<p>Turn the shaft periodically when the motor design and storage instructions allow it. Rotate it through a partial turn so the bearing position changes, while keeping guards and shaft protection in place. Do not spin a motor whose bearing is already gritty, whose shaft has been damaged or whose fan cover contains packed material. If the storage period exceeds the greasing interval in the motor manual, arrange bearing assessment or re-greasing before first start rather than relying on a short test run.<\/p>\n<p>For distributor stock, keep standard fixed-speed motors and variable-frequency machines clearly separated. Their winding insulation, cooling, bearings and speed limits may differ even when the external frame looks similar. Correct stock identification prevents a VFD motor from being released for the wrong project and makes it possible to retrieve the original test record later.<\/p>\n<h2 id=\"insulation-resistance\">Use the insulation reading to make a decision<\/h2>\n<p>Before any supply or drive cable is connected, isolate the motor and measure insulation resistance with a tester suited to its voltage class. For a low-voltage three-phase motor, measurements are normally made from each winding to the frame with the winding isolated from the supply. Record the test voltage, ambient temperature and humidity, because the raw number changes with conditions and test practice.<\/p>\n<p>Judge the result against the motor specification and its despatch record, not just against a single familiar number on a meter. An unexpectedly low value, a reading that keeps falling, a large difference between phases or visible moisture in the terminal box deserves investigation. Do not start the motor simply because the insulation reading rose after the terminal box was wiped dry; the moisture may still be inside the winding.<\/p>\n<p>If moisture is the established cause, dry the winding by a controlled method appropriate to the insulation system and monitor the resistance as it rises. Let the winding cool to a stable temperature and measure it again before considering the motor dry. Burning insulation, a persistent phase imbalance or contamination that does not disappear after drying points to a winding problem, not something to hide with a short low-voltage run.<\/p>\n<h2 id=\"first-start-checks\">Prove the installation before full load is applied<\/h2>\n<p>Check the terminal links against the actual site voltage and confirm that the correct overload and protection settings are selected for the motor and driven load. Verify the earth connection, terminal-box gasket and cable glands. For a VFD installation, follow the drive manufacturer's limits for cable length, earthing, filters and switching frequency. Correct motor insulation does not correct a cable system that produces excessive common-mode voltage.<\/p>\n<p>Where the driven machine allows it, run the motor uncoupled or at reduced load first. Record current in all three phases, vibration, bearing temperature, noise and direction of rotation. Check that the cooling fan turns in the correct direction. Then connect the load and take the same measurements after alignment, belt tension and coupling condition have been set.<\/p>\n<p>A current imbalance or vibration that appears only after coupling is evidence about the installation, not automatic proof of a motor fault. Keep the no-load and loaded readings. They give maintenance a baseline for judging later overheating, bearing noise or supply problems, and they help the manufacturer see whether the first failure started before or after the driven equipment was connected.<\/p>\n<p>If the temperature rises immediately after loading, use the <a href=\"https:\/\/yaodamotor.com\/three-phase-motor-overheating-diagnosis\/\">three-phase motor overheating diagnosis guide<\/a> to separate overload, voltage imbalance and cooling problems. If noise or vibration changes after coupling, use the <a href=\"https:\/\/yaodamotor.com\/motor-vibration-and-bearing-failure-diagnosis\/\">motor vibration and bearing failure guide<\/a>. For a converter-fed application, check the <a href=\"https:\/\/yaodamotor.com\/variable-speed-electric-motors-selection-guide\/\">variable-speed motor selection guide<\/a> before changing the speed range, cable length or drive settings.<\/p>\n<h2 id=\"warranty-evidence\">What Yaoda needs when the first start fails<\/h2>\n<p>A useful warranty enquiry gives our engineers the complete sequence rather than only a photograph of a burnt winding. Send the nameplate, despatch record, receiving date, storage location, insulation readings with test conditions, terminal-box condition, cable and drive details, first-run current and vibration readings, and photographs taken before cleaning.<\/p>\n<p>That information lets us check whether the motor was built to the ordered configuration and whether the evidence fits moisture ingress, bearing standstill damage, a cable or drive problem, incorrect connection or a winding defect. Replacement is not automatically the right answer when the cause of the first failure can be corrected and the motor itself remains sound.<\/p>\n<p>If you are holding Yaoda motors in stock or commissioning one after a long delay, send the nameplate photograph and storage dates to our engineering team. We can confirm the original build details and tell you which inspection points to record before the first start. For new projects, the same information helps us match the winding, bearing, cooling and protection arrangement to the actual operating conditions. Distributors can also review the <a href=\"https:\/\/yaodamotor.com\/ye3-series-h80-355-high-efficiency-three-phase-asynchronous-motor\/\">IE3 motor range<\/a> and higher-efficiency alternatives before repeating an old specification.<\/p>\n<p><a href=\"\/contact-us\/\">Send motor storage details and first-start readings to Yaoda \u2192<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Consejos sobre el almacenamiento y la primera puesta en marcha de los ingenieros de f\u00e1brica de Yaoda Motor: c\u00f3mo evitar la humedad y los fallos en los cojinetes y el aislamiento de los motores trif\u00e1sicos.<\/p>","protected":false},"author":1,"featured_media":426,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[11],"tags":[],"class_list":["post-976","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/posts\/976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/comments?post=976"}],"version-history":[{"count":6,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/posts\/976\/revisions"}],"predecessor-version":[{"id":985,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/posts\/976\/revisions\/985"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/media\/426"}],"wp:attachment":[{"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/media?parent=976"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/categories?post=976"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yaodamotor.com\/es\/wp-json\/wp\/v2\/tags?post=976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}